An analyzer that is simpler, more cost-effective, faster, smaller, and more durable is the Stat Profile Prime. Nova Biomedical innovative Microsensors CardTM technology is combined with the cutting-edge consumer microelectronics.



System with no need for maintenance:

Individual cartridges for calibrators, sensors, and liquid quality control (QC) are included in the Stat Profile Prime analyzer's distinctive cartridge system.


Maximum uptime for the analyzer:

In terms of analyzer uptime, individual cartridges offer a significant advantage over integrated sensor/calibrator cartridge systems.

Instant cartridge replacement:

Each cartridge is simple to use and can be replaced in a matter of seconds. The installation date, time, test parameters, lot number, and utilization of cartridges are all automatically recorded by the cartridge RFID technology. When only a calibrator cartridge is used, there is a significant reduction in analyzer uptime compared to combined cartridge systems, which require wait times of two to four hours. This further reduces the amount of warm-up time.

Separate cartridges save money:

When compared to integrated cartridge systems, which are prone to waste and lack flexibility, each cartridge offers a less expensive alternative. For instance, calibrators require more sensor cartridges than analyzers do in low-volume settings, while analyzers require more in high-volume settings. Using the Stat Profile Prime analyzer's individual sensor and calibrator cartridges cuts costs in both scenarios. When compared to combined cartridge systems, these cartridges eliminate waste.

Technology For Micro-Sensor Cards

Accuracy:

The well-established Nova biosensor technology is utilized in all Stat Profile Prime tests, and the sensor card format is used.

Always-on readiness:

The Micro-Sensor cards can be set up in a variety of ways:

  • 400 samples
  • 200 samples 

The Micro-Sensor cards are automatically calibrated and always prepared for direct analysis.

Protective clothing:

To prevent blood clots from obstructing the sample flow through sensor cartridges, a unique Clot Block TM flow path was developed.


The Quickest Replacement Time:

When compared to other cartridge systems, which typically need more than an hour to calibrate and remain unstable even after frequent re-calibrations, drift, and reduced throughput for even longer periods, the Micro-Sensor cards can be warmed, replaced, and calibrated in half the time.

True Liquid QC That Is Automated

The Only Trustworthy Analyzer Test Is True Liquid QC:

Electronic quality control (QC) is being phased out by federal regulations (CLIA) in the United States and replaced with true QC based on liquids. In order to guarantee laboratory precision and uncompromising quality, the Stat Profile Prime analyzer incorporates both continuous electronic self-monitoring and automated, true liquid QC.

Daily QC Is Automated With Tri-level QC Cartridges:

A supply of liquid QC material for 30 days is included in the QC cartridges. At intervals set by the user, controls are executed automatically. Any analyte that exceeds QC limits is disabled by an optional QC lockout feature.

Straightforward compliance with CLIA QC:

The Stat Profile Prime analyzer's automated quality control system satisfies all of the most recent CLIA requirements.1 The liquid quality controls validate the entire analytical procedure for each analyte at multiple concentration levels and follow the same sample pathway as the blood specimen. Statistics about quality control are kept automatically.

Complete Automation:

One of the aspects of critical care testing that takes the most time is manually running the QC. Every week, Stat Profile Prime's automated, true liquid QC saves time. It eliminates the need to create, implement, and document a lengthy, risk-based quality assessment and customized QC plan.

Monitoring of quality in addition:
A real-time, sample-to-sample guarantee of correct performance is provided by the Stat Profile Prime analyzer, which provides an alternative to liquid QC by continuously monitoring the performance and status of all analytical components. Reagents, sensors, sample integrity, calibrations, electronics, and software are all examples of these components.

Ten critical care tests with 60-second results:

  • pH, PO2, PCO2, K, iCa, Glu, Lac, and Hct, NaCl.
  • Microsamples from the venous, arterial, or capillary system: 100 ml for the entire menu
  • Rapid processing: 45 samples per hour or more

Connectivity in both directions:

Patient demographics, test orders, and patient identifiers can also be downloaded from By means of connect HIS or LIS to the Stat Profile Prime analyzer via the bidirectional interface.

For the purpose of the medical record, the software effortlessly captures precise and complete test records. Encryption and comprehensive cybersecurity protection are also included to safeguard PHI and provide an additional layer of defense against attempts to access a hospital's network.

Simple sampling from tubes, ampoules, syringes, and capillaries:

The user is protected from accidentally touching the sample probe by a one-of-a-kind safety sample port. All sample containers can easily access this sample port.

Color touchscreen with high definition and ease of use:

The touchscreen requires very little instruction and can be operated with simple, easy-to-follow prompts.

Start a complete 10-test profile in three easy steps:

Scan or enter the patient's ID by pressing "Start."

Scanner for barcodes built in:

The sample port's 1D/2D barcode scanner makes it possible to quickly and without error enter patient and operator IDs. Pre-analytical error can be further reduced by using the optional wireless external barcode scanner for positive patient identification.

Size for use at the point of care:

Because it is so small, the analyzer can be used almost anywhere in the hospital or on a mobile cart that has a battery backup.